ZBD1850NII
GE Monogram® 18" Dishwasher
Dimensions and Installation Information (in Inches)
• The dishwasher must be installed so that the drain hose is
no more than 10 feet in length for proper drainage.
• The dishwasher must be fully enclosed on the top, sides
and back, and must not support any part of the enclosure.
ClearanCeS:
When installed into a corner, allow 2" min. clearance
between dishwasher and adjacent cabinet,wall or other
appliances. Allow 25-5/8" min. clearance from the front of
the dishwasher for door opening.
Countertop
Dishwasher
25-5/8"
aDa-Compliant ZBD1850nII:
Installation below 34"-high countertops
Clearance for Door
A reduced-height installation (32-1/2" min.) beneath a
34" countertop can be accomplished by removing the
front leveling legs. The rear legs should be screwed in
flush with the bottom support, as shipped. The front of
the dishwasher must be shimmed to level it. Water and
electrical must be routed through the back wall.
Opening 2" Minimum
Installation Information:
Before installing, consult installation instructions packed
with product, or available at Monogram.com, for current
dimensional data.
electrical requirements
The dishwasher must be supplied with 120V, 60Hz, and
connected to an individual properly grounded branch
circuit protected by a 15- or 20-amp circuit breaker or
time-delay fuse.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
As an EnErgy StAr®
Listed by
partner, gE has determined
that this product meets the
EnErgy StAr guidelines
for energy efficiency.
Underwriters
Laboratories
Specification Created 6/08
150050
|